N.Y. Comp. Codes R. & Regs. tit. 12, § 39.9
(4) The board may authorize temporary deviations from the following quantity and distance tables when compliance therewith entails practical difficulties or unnecessary hardship, provided public safety is preserved.
TABLE 1
HIGH EXPLOSIVES QUANTITY AND DISTANCE TABLE
| Explosives in Pounds | Distances in Feet | ||||
|---|---|---|---|---|---|
| Pounds over | Pounds Not Over | From Nearest Building | From Nearest Railway | From Nearest Highway | Separation of Magazines |
| 0 — | 5 | 140 | 60 | 60 | 12 |
| 5 — | 10 | 180 | 70 | 70 | 16 |
| 10 — | 20 | 220 | 90 | 90 | 20 |
| 20 — | 30 | 250 | 100 | 100 | 22 |
| 30 — | 40 | 280 | 110 | 110 | 24 |
| 40 — | 50 | 300 | 120 | 120 | 28 |
| 50 — | 75 | 340 | 140 | 140 | 30 |
| 75 — | 100 | 380 | 150 | 150 | 32 |
| 100 — | 125 | 400 | 160 | 160 | 36 |
| 125 — | 150 | 430 | 170 | 170 | 38 |
| 150 — | 200 | 470 | 190 | 190 | 42 |
| 200 — | 250 | 510 | 210 | 210 | 46 |
| 250 — | 300 | 540 | 220 | 220 | 48 |
| 300 — | 400 | 590 | 240 | 240 | 54 |
| 400 — | 500 | 640 | 260 | 260 | 58 |
| 500 — | 600 | 680 | 270 | 270 | 62 |
| 600 — | 700 | 710 | 290 | 290 | 64 |
| 700 — | 800 | 750 | 300 | 300 | 66 |
| 800 — | 900 | 780 | 310 | 310 | 70 |
| 900 — | 1,000 | 800 | 320 | 320 | 72 |
| 1,000 — | 1,200 | 850 | 340 | 330 | 78 |
| 1,200 — | 1,400 | 900 | 360 | 340 | 82 |
| 1,400 — | 1,600 | 940 | 380 | 350 | 86 |
| 1,600 — | 1,800 | 980 | 390 | 360 | 88 |
| 1,800 — | 2,000 | 1,010 | 410 | 370 | 90 |
| 2,000 — | 2,500 | 1,090 | 440 | 380 | 98 |
| 2,500 — | 3,000 | 1,160 | 470 | 390 | 104 |
| 3,000 — | 4,000 | 1,270 | 510 | 420 | 116 |
| 4,000 — | 5,000 | 1,370 | 550 | 450 | 122 |
| 5,000 — | 6,000 | 1,460 | 590 | 470 | 130 |
| 6,000 — | 7,000 | 1,540 | 620 | 490 | 136 |
| 7,000 — | 8,000 | 1,600 | 640 | 500 | 144 |
| 8,000 — | 9,000 | 1,670 | 670 | 510 | 150 |
| 9,000 — | 10,000 | 1,730 | 690 | 520 | 156 |
| 10,000 — | 12,000 | 1,750 | 740 | 540 | 164 |
| 12,000 — | 14,000 | 1,770 | 780 | 550 | 174 |
| 14,000 — | 16,000 | 1,800 | 810 | 560 | 180 |
| 16,000 — | 18,000 | 1,880 | 840 | 570 | 188 |
| 18,000 — | 20,000 | 1,950 | 870 | 580 | 196 |
| 20,000 — | 25,000 | 2,110 | 940 | 630 | 210 |
| 25,000 — | 30,000 | 2,260 | 1,000 | 680 | 224 |
| 30,000 — | 35,000 | 2,410 | 1,050 | 720 | 238 |
| 35,000 — | 40,000 | 2,550 | 1,100 | 760 | 248 |
| 40,000 — | 45,000 | 2,680 | 1,140 | 800 | 258 |
| 45,000 — | 50,000 | 2,800 | 1,180 | 840 | 270 |
| 50,000 — | 55,000 | 2,920 | 1,220 | 880 | 280 |
| 55,000 — | 60,000 | 3,030 | 1,260 | 910 | 290 |
| 60,000 — | 65,000 | 3,130 | 1,290 | 940 | 300 |
| 65,000 — | 70,000 | 3,220 | 1,320 | 970 | 310 |
| 70,000 — | 75,000 | 3,310 | 1,350 | 1,000 | 320 |
| 75,000 — | 80,000 | 3,390 | 1,380 | 1,020 | 330 |
| 80,000 — | 85,000 | 3,460 | 1,410 | 1,040 | 340 |
| 85,000 — | 90,000 | 3,520 | 1,440 | 1,060 | 350 |
| 90,000 — | 95,000 | 3,580 | 1,460 | 1,080 | 360 |
| 95,000 — | 100,000 | 3,630 | 1,490 | 1,090 | 370 |
| 100,000 — | 110,000 | 3,670 | 1,540 | 1,100 | 390 |
| 110,000 — | 120,000 | 3,710 | 1,580 | 1,110 | 410 |
| 120,000 — | 130,000 | 3,750 | 1,620 | 1,120 | 430 |
| 130,000 — | 140,000 | 3,780 | 1,670 | 1,130 | 450 |
| 140,000 — | 150,000 | 3,800 | 1,700 | 1,140 | 470 |
| 150,000 — | 160,000 | 3,870 | 1,740 | 1,160 | 490 |
| 160,000 — | 170,000 | 3,930 | 1,780 | 1,180 | 510 |
| 170,000 — | 180,000 | 3,980 | 1,810 | 1,200 | 530 |
| 180,000 — | 190,000 | 4,020 | 1,840 | 1,210 | 550 |
| 190,000 — | 200,000 | 4,060 | 1,870 | 1,220 | 570 |
| 200,000 — | 210,000 | 4,110 | 1,910 | 1,240 | 590 |
| 210,000 — | 230,000 | 4,200 | 1,960 | 1,270 | 630 |
| 230,000 — | 250,000 | 4,310 | 2,020 | 1,300 | 670 |
| 250,000 — | 275,000 | 4,430 | 2,080 | 1,340 | 720 |
| 275,000 — | 300,000 | 4,550 | 2,150 | 1,380 | 770 |
TABLE 2
LOW EXPLOSIVES QUANTITY AND DISTANCE TABLE
| Pounds Over | Pounds Not Over | Inhabited Building (Distance in Feet) | Public Railroad and Highway (Distance in Feet) | Aboveground Magazine (feet) |
|---|---|---|---|---|
| 0 — | 1,000 | 75 | 75 | 50 |
| 1,000 — | 5,000 | 115 | 115 | 75 |
| 5,000 — | 10,000 | 150 | 150 | 100 |
| 10,000 — | 20,000 | 190 | 190 | 125 |
| 20,000 — | 30,000 | 215 | 215 | 145 |
| 30,000 — | 40,000 | 235 | 235 | 155 |
| 40,000 — | 50,000 | 250 | 250 | 165 |
| 50,000 — | 60,000 | 260 | 260 | 175 |
| 60,000 — | 70,000 | 270 | 270 | 185 |
| 70,000 — | 80,000 | 280 | 280 | 190 |
| 80,000 — | 90,000 | 295 | 295 | 195 |
| 90,000 — | 100,000 | 300 | 300 | 200 |
| 100,000 — | 200,000 | 375 | 375 | 250 |
| 200,000 — | 300,000 | 450 | 450 | 300 |
TABLE 3
AMMONIUM NITRATE AND BLASTING AGENTS QUANTITY AND DISTANCE TABLE
| Donor Weight | Minimum Separation Distance of Receptor When Barricaded in Feet (See § 39.11 [a]) | Minimum Thickness of Artificial Barricades in Inches (See § 39.11[d]) | ||
|---|---|---|---|---|
| Pounds Over | Pounds Not Over | Ammonium Nitrate (See § 39.11[b]) | Blasting Agent (See § 39.11[c]) | |
| 0 — | 100 | 3 | 11 | 12 |
| 100 — | 300 | 4 | 14 | 12 |
| 300 — | 600 | 5 | 18 | 12 |
| 600 — | 1,000 | 6 | 22 | 12 |
| 1,000 — | 1,600 | 7 | 25 | 12 |
| 1,600 — | 2,000 | 8 | 29 | 12 |
| 2,000 — | 3,000 | 9 | 32 | 15 |
| 3,000 — | 4,000 | 10 | 36 | 15 |
| 4,000 — | 6,000 | 11 | 40 | 15 |
| 6,000 — | 8,000 | 12 | 43 | 20 |
| 8,000 — | 10,000 | 13 | 47 | 20 |
| 10,000 — | 12,000 | 14 | 50 | 20 |
| 12,000 — | 16,000 | 15 | 54 | 25 |
| 16,000 — | 20,000 | 16 | 58 | 25 |
| 20,000 — | 25,000 | 18 | 65 | 25 |
| 25,000 — | 30,000 | 19 | 68 | 30 |
| 30,000 — | 35,000 | 20 | 72 | 30 |
| 35,000 — | 40,000 | 21 | 76 | 30 |
| 40,000 — | 45,000 | 22 | 79 | 35 |
| 45,000 — | 50,000 | 23 | 83 | 35 |
| 50,000 — | 55,000 | 24 | 86 | 35 |
| 55,000 — | 60,000 | 25 | 90 | 35 |
| 60,000 — | 70,000 | 26 | 94 | 40 |
| 70,000 — | 80,000 | 28 | 101 | 40 |
| 80,000 — | 90,000 | 30 | 108 | 40 |
| 90,000 — | 100,000 | 32 | 115 | 40 |
| 100,000 — | 120,000 | 34 | 122 | 50 |
| 120,000 — | 140,000 | 37 | 133 | 50 |
| 140,000 — | 160,000 | 40 | 144 | 50 |
| 160,000 — | 180,000 | 44 | 158 | 50 |
| 180,000 — | 200,000 | 48 | 173 | 50 |
| 200,000 — | 220,000 | 52 | 187 | 60 |
| 220,000 — | 250,000 | 56 | 202 | 60 |
| 250,000 — | 275,000 | 60 | 216 | 60 |
| 275,000 — | 300,000 | 64 | 230 | 60 |
(b) Quantity and distance requirements for blasting caps and detonating cord.
(1) Blasting caps. The quantity and distance requirements for blasting caps shall be as follows:
(2) Detonating cord. The quantity and distance requirements for detonating cord shall be as follows:
(a) Quantity and distance tables.