N.Y. Comp. Codes R. & Regs. tit. 12, § 36-2.9
(4) No dry vegetation and no trees or greens containing pitch or resin are permitted. Flowers and decorative greens which do not contain pitch or resin are permitted only when freshly cut or living and not flammable. No flammable material whatever is permitted except as provided in paragraphs (1) and (2) above. Exception:
Exception:
One nonflameproofed resinous Christmas tree is permitted in the discretion of the enforcing authority in a place of public assembly whose exits are in full compliance with this Part provided the following conditions are observed:
6. No flammable decorations and no lights other than electric lights shall be used on such tree.
(1) Combustible materials shall not be stored in basements or cellars of places of public assembly except under one of the following conditions:
(2) Combustible materials shall not be deemed to include fuel oil or coal stored for use in the heating of the building.
(c) Storage in or about stairways.
(3) No flammable liquids, gases or materials shall under any circumstances be stored in or near a stairway or stair enclosure.
(d) Use of combustible or volatile fluids.
No apparatus in which any combustible or volatile fluid is used in the preparation of foods, refreshments or other materials is permitted in a lobby, foyer or auditorium of a place of public assembly. Combustible or volatile as used in this subdivision includes any fluid having a closed cup flash point below 400 degrees Fahrenheit.
(e) Kitchens and service pantries.
(6) An approved 10 pound carbon dioxide or two and one-half gallon foam fire extinguisher shall be provided and securely mounted on the wall in plain sight and readily accessible. Extinguishers shall be checked annually and recharged after use and shall be tagged to indicate when this was done and by whom.
(f) Assembly halls in fire houses.
The storage of fire apparatus is permitted in the same building with an assembly hall only if the apparatus room is separated from the assembly hall by construction having a fire-resistance rating of at least one hour. Doors opening into the apparatus room shall be at least one hour self-closing fire doors. Doors leading into the apparatus room shall not constitute required exits from the assembly hall.
(g) Projection screens.
Screens for projections of pictures shall be either made of incombustible materials or treated so as to neither ignite nor actively support combustion.
(b) Storage in basements and cellars.
(a) Decorations.