N.Y. Comp. Codes R. & Regs. tit. 12, § 23-4.5
(h) The maximum distance between the lowest brace and the bottom of the excavation shall not exceed three feet, except where the sheeting or soldier beam is embedded as stipulated in subdivision (i) below.
TABLE IV
MINIMUM SIZES OF STRINGERS AND BRACES
Wide Trenches—Horizontal Cross-Braces More Than Four Feet But Not Longer Than Eight Feet
| Trench Depth | Type of Soil | Vertical Spacing of Stringers | Horizontal Spacing of Cross–Braces | |||||||
|---|---|---|---|---|---|---|---|---|---|---|
| 4 Feet | 6 Feet | |||||||||
| Stringers | Braces | Stringers | Braces | Stringers | Braces | Stringers | Braces | |||
| 5 to 10 ft. | Stiff cohesive | 4 ft. max. | 4 × 4 | 4 × 4 | 6 × 6 or 4 ×8 | 4 × 6 | 6 × 6 | 4 × 6 | 8 × 8 | 6 × 6 |
| Noncohesive | Over 4 ft. to 6 ft. max. | 6 × 6 or 4 ×8 | 4 × 6 | 6 × 6 | 6 × 6 | 6 × 8 | 6 × 8 | 8 × 10 | 6 × 8 | |
| Soft cohesive and wet flowing | 4 ft. max. | 6 × 6 | 6 × 6 | 6 × 10 | 6 × 6 | 8 × 10 | 6 × 6 | 10 × 12 | 8 × 8 | |
| Over 10 to 20 ft. | Stiff cohesive and noncohesive | 4 ft. max. | 4 × 6 | 4 × 6 | 6 × 6 | 6 × 6 | 8 × 8 or 6 ×10 | 6 × 6 | 10 × 10 | 8 × 8 |
| Soft cohesive and wet flowing | 4 ft. max. | 6 × 8 | 6 × 8 | 8 × 10 | 6 × 10 | 10 × 12 | 8 × 10 | * | * | |
| Over 20 ft. | For any trench over 20 feet in depth the sheeting, shoring and bracing system shall be designed by a professional engineer licensed to practice in the State of New York. Such design plan, including design analysis and specifications, shall be submitted to the board for special approval before any work is performed on such excavation. |
*
Sizes of timber for such conditions become excessive. A special structure designed by a professional engineer licensed to practice in the State of New York shall be constructed and used for the specific condition involved.
Note: Timber sizes are nominal or trade dimensions.
(i) If the bottom of the sheeting or soldier beam is embedded below the bottom of the excavation, the maximum distance between the lowest brace and the bottom of the excavation shall not exceed the vertical spacing for braces allowed in Tables III and IV of this Subpart. The minimum depth of embedment of the sheeting or soldier beam shall be three feet. The actual depth of each such embedment shall be such that there is no significant movement of the bottom of the sheeting or soldier beam.
Exception:
Where the operation being performed, such as laying large diameter concrete pipe or reinforced concrete culverts, precludes the placing of vertical bracing as specified in subdivisions (h) and (i) above, the vertical spacing may be in accordance with a specific design and plans made by a professional engineer licensed to practice in the State of New York. Such specified bracing system shall be designed so that the sheeting and shoring will withstand all the forces intended to be imposed thereon. Copies of the design and plans of such sheeting and shoring system shall be kept at the job site available for examination by the commissioner.
The use of Tables III and IV shall be subject to the following requirements: