N.Y. Comp. Codes R. & Regs. tit. 12, § 21.9
(3) Upon discovery of any substantial defect or abnormal condition in the scaffold or any part thereof, the scaffold shall be placed out of operation until such time as the abnormality or defect has been corrected and the scaffold restored to its normal condition.
(c) Suspended scaffolds—75 feet or more.
Every suspended scaffold so used including both manually or power operated types shall be approved if it is or is intended to be suspended from any point which has an elevation 75 feet or more above the nearest street or ground surface.
(d) Suspended scaffolds—not exceeding 75 feet; lifelines.
(2) Each person working on such a suspended scaffold shall be provided with and shall use an approved safety belt. Each belt shall have its own lifeline, which shall consist of a hanging line and a tail line. The tail line shall be of minimum practical length and shall be attached to the hanging line by an approved special device to allow vertical adjustment of the point of attachment. The lifeline shall be securely attached to a sufficient anchorage. Note:
Note:
See section 23.30 of Industrial Code Part (Rule No.) 23.
(a) Compliance with Part (Rule No.) 23.
Every scaffold used for cleaning by this method shall be designed, constructed, installed, operated and maintained in compliance with all relevant provisions of Part (Rule No.) 23, Protection of Persons Employed in Construction and Demolition Work, as amended, except as the board may otherwise provide in this Part (rule) or in a resolution of approval of a specific scaffold or type thereof.
(b) Maintenance and inspection requirements.