N.M. Code R. § 8.369.2.74
Doors
Effective Jul 1, 2026State of New Mexico
- A. All exit doors must have a minimum width of 36 inches.
- B. All sleeping room doors must have at least one and three quarter inches bonded solid core, with a minimum width of 32 inches.
- C. All doors to toilet and bathing facilities must have a minimum width of 24 inches.
- D. Locks on doors to toilets must be of a type that the lock can be released from the outside.
- E. Exit doors leading to the outside of a facility with a capacity of 10 or more children must open outward.
- F. Exit doors leading to the outside of a facility must be provided with a night latch, dead bolt or security chain, provided such devices open from the inside without the use of a key or tool and are mounted at a height not to exceed 48 inches above the finished floor.
- G. Sleeping room doors for non-mobile children must be at least one and three quarter inches bonded solid core, with a minimum width of 44 inches.
- H. Each sleeping room housing non-mobile children must have a 44-inch exit door leading directly to the outside.
[8.369.2.74 NMAC - N/E, 7/1/2026]