20.9.5.13
ADDITIONAL OPERATING REQUIREMENTS FOR RECYCLING FACILITIES THAT ACCEPT SOLID WASTE AND PROCESSING FACILITIES. Owners and operators of recycling facilities that accept solid waste and processing facilities shall:
- A. prominently post key operational procedures;
B. store any special wastes:
(1) in separate, clearly marked areas;
(2) in covered buildings; and
(3) in covered leak-proof containers, or in tanks labeled with a description of the contents and the date the wastes were placed in storage;
- C. provide audible signals to alert operating personnel of critical operating unit malfunctions;
- D. provide sampling points of each process stream that do not interfere with normal facility operation;
- E. provide for periodic wash-down or other cleanup of the facility and dispose of any waste waters in accordance with all applicable state and federal regulations;
- F. store waste residues by means that prevent the material and containers from falling, leaking, blowing, and exposure to the weather;
- G. store all materials that are physically or chemically incompatible in separate areas;
- H. provide storage capacity for any special waste by-products generated during the initial start-up characterization period;
- I. store any material containers that have the potential of discharging any oils, polychlorinated biphenyls (PCB's), battery acid, battery alkalines, or other liquids in a restricted area identified by signs on a covered, substance-compatible, bermed containment pad; and
- J. include a schedule and contacts for removal of stored wastes in the operations and maintenance manual.
[20.9.5.13 NMAC - Rp, 20 NMAC 9.1.IV.406, 8/2/2007]