N.M. Code R. § 20.7.3.703
H. The required absorption area shall be calculated by the following formula: ABSORPTION AREA = Q X AR, where: Q = the design flow rate in gallons per day; AR = application rate (from Table 703.1)
Table 703.1: Application Rates by Soil Types for Conventional Treatment Systems
Soil Type Soil Texture Application Rate (AR) (sq. ft./gal/day) Ia Ib Coarse Sand or up to 30% gravel Medium Sand, Loamy Sand 1.25 (See Subsection F of 20.7.3.703 NMAC) 2.00 II Sandy Loam, Fine Sand , Loam 2.00 III Silt, Silt Loam, Clay Loam, Silty Clay Loam, Sandy Clay Loam 2.00 IV Sandy Clay, Silty Clay, Clay 5.00 (See Subsection G of 20.7.3.703 NMAC)
Soil Type
Soil Texture
Application Rate
(AR)
(sq. ft./gal/day)
Ia
Ib
Coarse Sand
or up to 30% gravel
Medium Sand, Loamy Sand
1.25
(See Subsection F of 20.7.3.703 NMAC)
2.00
II
Sandy Loam, Fine Sand , Loam
2.00
III
Silt, Silt Loam, Clay Loam, Silty Clay Loam,
Sandy Clay Loam
2.00
IV
Sandy Clay, Silty Clay, Clay
5.00
(See Subsection G of 20.7.3.703 NMAC)
I. The gravel content of in-place natural soil shall not exceed 30%. The department may identify and map areas of the state where groundwater is not at risk from microbial contamination from on-site liquid waste disposal systems that discharge into gravel, and where gravel contents greater than 30% may be allowed. The following hydrogeologic conditions may be considered when determining if groundwater is not at risk:
(1) groundwater does not exist;
(2) uppermost groundwater contains a total dissolved solids concentration greater than 10,000 milligrams per liter;
(3) uppermost groundwater occurs under confined conditions; and
(4) uppermost groundwater occurs at a depth of 30 feet or greater with at least four feet of suitable soil in the vadose zone.
J. Disposal trenches:
(1) The total absorption area shall be calculated utilizing the total trench bottom and sidewall area below the distribution pipe.
(2) The total absorption area shall not exceed seven square feet per linear foot of trench.
(3) A minimum of 300 square feet of absorption area shall be provided for each system exclusive of any hard pan, caliche, rock, clay or other impervious formations.
[20.7.3.703 NMAC - Rp, 20.7.3.703 NMAC, 9/1/13; A, 9/1/13]