N.M. Code R. § 20.2.50.122
B. Emission standards:
(2) An existing natural gas-driven pneumatic pump shall comply with the requirements of 20.2.50.122 NMAC within three years of the effective date of this Part.
(3) An owner or operator shall ensure that its existing natural gas-driven pneumatic controllers comply with the requirements of 20.2.50.122 NMAC according to the following schedule:
Table 1 – WELL SITES, STANDALONE TANK BATTERIES, GATHERING AND BOOSTING STATIONS
Total Historic Percentage of Non-Emitting Controllers Total Required Percentage of Non-Emitting Controllers by January 1, 2024 Total Required Percentage of Non-Emitting Controllers by January 1, 2027 Total Required Percentage of Non-Emitting Controllers by January 1, 2030 > 75% 80% 85% 90% > 60-75% 80% 85% 90% > 40-60% 65% 70% 80% > 20-40% 45% 70% 80% 0-20% 25% 65% 80%
Total Historic Percentage of Non-Emitting Controllers
Total Required Percentage of Non-Emitting Controllers by January 1, 2024
Total Required Percentage of Non-Emitting Controllers by January 1, 2027
Total Required Percentage of Non-Emitting Controllers by January 1, 2030
> 75%
80%
85%
90%
> 60-75%
80%
85%
90%
> 40-60%
65%
70%
80%
> 20-40%
45%
70%
80%
0-20%
25%
65%
80%
Table 2 – TRANSMISSION COMPRESSOR STATIONS AND GAS PROCESSING PLANTS
Total Historic Percentage of Non-Emitting Controllers Total Required Percentage of Non-Emitting Controllers by January 1, 2024 Total Required Percentage of Non-Emitting Controllers by January 1, 2027 Total Required Percentage of Non-Emitting Controllers by January 1, 2030 > 75% 80% 95% 98% > 60-75% 80% 95% 98% > 40-60% 65% 95% 98% > 20-40% 50% 95% 98% 0-20% 35% 95% 98%
Total Historic Percentage of Non-Emitting Controllers
Total Required Percentage of Non-Emitting Controllers by January 1, 2024
Total Required Percentage of Non-Emitting Controllers by January 1, 2027
Total Required Percentage of Non-Emitting Controllers by January 1, 2030
> 75%
80%
95%
98%
> 60-75%
80%
95%
98%
> 40-60%
65%
95%
98%
> 20-40%
50%
95%
98%
0-20%
35%
95%
98%
(4) Standards for natural gas-driven pneumatic controllers:
(b) owners and operators of existing pneumatic controllers shall meet the required percentage of non-emitting controllers within the deadlines in tables 1 and 2 of Paragraph (3) of Subsection B of 20.2.50.122 NMAC, and shall comply with the following:
(vi) if after January 1, 2027, an owner or operator’s remaining pneumatic controllers are not cost-effective to retrofit, the owner or operator may submit a cost analysis of retrofitting those remaining units to the department. The department shall review the cost analysis and determine whether those units qualify for a waiver from meeting additional retrofit requirements.
(c) owners and operators of existing natural gas driven pneumatic controllers shall demonstrate compliance with tables 1 and 2 of Paragraph (3) of Subsection B of 20.2.50.122 NMAC, on January 1, 2024, January 1, 2027, and January 1, 2030, as follows:
(ii) determine the percentage of non-emitting controllers by using the following equation for table 1 and table 2 facilities separately:
Total Percentage of Non-Emitting Controllers =
100 – ((total emitting controllers / total historic controller count) x 100)
(5) Standards for natural gas-driven pneumatic diaphragm pumps:
C. Monitoring requirements:
(4) Within two years of the effective date of this Part, the owner or operator’s data systems shall contain the following for each in-service natural gas-driven pneumatic controller:
D. Recordkeeping requirements:
(5) The owner or operator shall maintain an electronic record for each natural gas-driven pneumatic controller. The record shall include the following:
(c) name of the person(s) conducting the inspection;
(7) The owner or operator shall maintain a record for a natural gas-driven pneumatic pump with an emission rate greater than zero and the associated pump number at the facility. The record shall include:
[20.2.50.122 NMAC - N, 08/05/2022]