N.M. Code R. § 20.2.31.112
C. Instruments and sampling systems installed and used pursuant to this section shall be calibrated in accordance with the methods prescribed by manufacturer's recommended zero adjustment and calibration check procedures at least once every 24-hours of operation, unless the instrument manufacturer specifies or recommends calibration checks more frequently; provided however, that no calibration and adjustments shall be required during the period when coal burning equipment is not operating. The reference method shall be consistent with the method for manual sampling of sulfur dioxide specified in 20.2.31.111 NMAC. The owner or operator of coal burning equipment shall retain for a period of two years all raw data and quality assurance measurements and procedures.
[11/30/95; 20.2.31.112 NMAC - Rn, 20 NMAC 2.31.112 10/31/02]