Effective Apr 30, 2019(See Revision Note at Chapter Heading for Saf-C 5000) #6055, eff 7-1-95; amd by #7481, eff 4-25-01; paragraphs (a)-(d) and (f) EXPIRED: 7-1-03; amd by #8117, INTERIM, eff 7-14-04; paragraphs (a)-(d) and (f) EXPIRED: 1-10-05; amd by #8261, eff 1-21-05, amd by #9471, INTERIM, eff 5-15-09, EXPIRED: 11-11-09 New. #9765-A, eff 8-2-10; ss by #12738, eff 4-30-19Commissioner, Department of Safety
- (a) Shells shall be carried from the storage area to the discharge site only by their bodies, and never by their fuses.
- (b) The safety cap protecting the fuse shall not be removed by the operator responsible for igniting the fuse until immediately before the shell shall be fired.
- (c) No smoking or open flames shall be allowed in the shell storage area if shells are present.
- (d) No attempt shall be made to repair a damaged shell or to attempt to dismantle a dry shell. The operator shall contact the supplier for proper disposal instructions.
- (e) Display fireworks that have become wet shall not be utilized even if dried out.
- (f) Displays shall not be set up during any rain or snow storm or displayed during any electrical storm or when the wind reaches a velocity of more than 20 miles per hours.
Source. (See Revision Note at Chapter Heading for Saf-C 5000) #6055, eff 7-1-95; amd by #7481, eff 4-25-01; paragraphs (a)-(d) and (f) EXPIRED: 7-1-03; amd by #8117, INTERIM, eff 7-14-04; paragraphs (a)-(d) and (f) EXPIRED: 1-10-05; amd by #8261, eff 1-21-05, amd by #9471, INTERIM, eff 5-15-09, EXPIRED: 11-11-09 New. #9765-A, eff 8-2-10; ss by #12738, eff 4-30-19