N.H. Code Admin. R. Saf-C 1610.11
Igloos, Tunnels, and Dugouts
Effective Aug 15, 2013#2220, eff 12-31-82; ss by #2837, eff 8-27-84; ss by #4584, eff 3-3-89; ss by #5996, INTERIM, eff 3-3-95, EXPIRES, 7-1-95; ss by #6054, eff 7-1-95, EXPIRED: 7-1-03 New. #8116, INTERIM, eff 7-14-04, EXPIRES: 1-10-05; ss by #8231, eff 12-20-04; ss by #10396, eff 8-15-13Commissioner, Department of Safety
- (a) Igloos, tunnels, and dugout storage facilities shall be constructed of reinforced concrete, masonry, metal or a combination of these materials. They shall have an earthmound covering of not less than 24 inches on the top, sides and rear.
- (b) Interior walls and floors shall be covered with a non-sparking material.
(c) Storage facilities of this type shall also be constructed in conformity with the requirements for buildings in reference to:
- (1) Floors, Saf-C 1610.03;
- (2) Doors, Saf-C 1610.07;
- (3) Locks, Saf-C 1610.08;
- (4) Ventilation, Saf-C 1610.09; and
- (5) Exposed metals, Saf-C 1610.10.
Source. #2220, eff 12-31-82; ss by #2837, eff 8-27-84; ss by #4584, eff 3-3-89; ss by #5996, INTERIM, eff 3-3-95, EXPIRES, 7-1-95; ss by #6054, eff 7-1-95, EXPIRED: 7-1-03 New. #8116, INTERIM, eff 7-14-04, EXPIRES: 1-10-05; ss by #8231, eff 12-20-04; ss by #10396, eff 8-15-13