(a) At a job site, the following shall be supplied by the licensee or registrant:
- (1) At least one operable, calibrated survey instrument for each exposure device or radiation machine in use;
- (2) A current whole body individual monitoring device such as: film badge, TLD, or OSL for each worker;
- (3) An operable, calibrated pocket dosimeter with a range of zero to 200 milliroentgens for each worker;
- (4) An operable, calibrated, alarming ratemeter for each worker; and
- (5) The appropriate barrier ropes and caution signs.
- (b) Each radiographer at a job site shall have available proof of valid certification issued by a certifying entity.
- (c) Industrial radiographic operations shall not be performed if any of the items in He‑P 4034.39(a) are not available at the job site or are inoperable.
- (d) During an inspection, DHHS/RHS shall terminate an operation if any of the items in He‑P 4034.39(a) are not available or operable, or if the required number of radiographic personnel is not present.
- (e) Operations terminated under the conditions of He‑P 4034.39(d) shall not be resumed until all required conditions are met.