N.H. Code Admin. R. He-P 4034.08
Locking of Radiographic Exposure Devices, Storage Containers and Source Changers
Effective Jul 19, 2025#6942, eff 2-1-99; ss by #8800, INTERIM, eff 2-1-07, EXPIRED: 7-31-07 New. #8959, eff 8-7-07; ss by #10983, eff 11-24-15; amd by #12626, eff 9-26-18; amd by #12930, eff 11-26-19; ss by #14325, eff 7-19-25, EXPIRES: 7-19-35Former Division of Public Health Services
- (a) Each radiographic exposure device shall have a lock or outer locked container designed to prevent unauthorized or accidental removal of the sealed source from its shielded position.
- (b) The exposure device, or its container, or both shall be kept locked (and if a keyed-lock, with the key removed at all times) when not under the direct surveillance of a radiographer or a radiographer’s assistant except at permanent radiographic installations as stated in He‑P 4034.22.
- (c) During radiographic operations the sealed source assembly shall be secured in the shielded position each time the source is returned to that position.
- (d) Each sealed source storage container and source changer shall have a lock or outer locked container designed to prevent unauthorized or accidental removal of the sealed source from its shielded position.
- (e) Storage containers and source changers shall be kept locked, and if a keyed-lock, with key removed at all times, when containing sealed sources except when under the direct surveillance of a radiographer or a radiographer’s assistant.
Source. #6942, eff 2-1-99; ss by #8800, INTERIM, eff 2-1-07, EXPIRED: 7-31-07 New. #8959, eff 8-7-07; ss by #10983, eff 11-24-15; amd by #12626, eff 9-26-18; amd by #12930, eff 11-26-19; ss by #14325, eff 7-19-25, EXPIRES: 7-19-35