The project-specific information required by Env-Wt 310.01(c)(1) or Env-Wt 311.03(b)(11), as applicable, for a C/M project shall be as follows:
- (a) A description of the scope of the project, the size of the impacts to aquatic resources, and the purpose of the project;
(b) An accurate drawing with existing and proposed structure dimensions clearly annotated to:
- (1) Document existing site conditions;
- (2) Detail the precise location of the project and show the impact of the proposed activity on jurisdictional areas;
- (3) Show existing and proposed contours at 2-foot intervals;
- (4) Show existing and proposed structure invert elevations on the plans; and
- (5) Use a scale based on standard measures of whole units, such as an engineering rule of one to 10, provided that if plans are not printed at full scale, a secondary scale shall be noted on the plans that identifies the half scale unit of measurement;
- (c) All easements and right-of-way acquisition area outlines in relation to the project;
- (d) The name of the professional engineer who developed the plans, whether an employee of the applicant or at a consulting firm; and
(e) An erosion control plan that shows:
- (1) Existing and proposed contours at 2-foot intervals, with existing contours shown with a lighter line weight and proposed contours shown with a heavier line weight such as a bold font; and
- (2) The outermost limit of all work areas, including temporary phasing work, with perimeter controls.
Source. #12805, eff 12-15-19