(a) Toilet facilities shall:
- (1) Include one toilet for every 10 persons in a resident camp;
- (2) Include one toilet for every 30 persons in a day camp;
- (3) Be located, constructed, and maintained to ensure safe and sanitary conditions; and
- (4) Contain at least one toilet for each gender with a door or curtain for privacy.
- (b) Urinals may be substituted for up to 1/3 of the toilets in toilet facilities for males.
- (c) Floors and walls in toilet facilities shall be sealed with polyurethane or paint up to a height of not less than 48 inches.
- (d) Badly worn or chipped toilet seats shall be repaired or replaced.
- (e) All toilet facilities shall be supplied with toilet paper at all times.
- (f) A sink for hand washing with soap and towels shall be available within or immediately outside the toilet facility.
(g) Privies shall meet the following conditions:
- (1) The privy shall be constructed in accordance with Env-Wq 1022.01;
(2) Privies shall be located:
- a. At least 100 feet from any place where food is prepared or served;
- b. At least 75 feet from any surface water; and
- c. At least 200 feet up-gradient of any well or spring;
(3) Privy contents shall be:
- a. Removed as often as necessary to prevent the pit from being filled to within one foot of the top of the pit; and
- b. Disposed of in accordance with Env-Wq 1600.
- (4) The contents of the pit shall be covered daily with lime or other suitable agent to eliminate insects and odors;
- (5) The materials for liming and disinfection shall be kept in proximity to the privy so as to be readily available for use;
- (6) The privy and the pit shall be made fly-tight and provided with self-closing lids; and
- (7) Clean and sanitary conditions shall be maintained at all times.
- (h) Chemical toilets shall be maintained and pumped by a septage hauler licensed in accordance with Env-Wq 1600.
Source. (See Revision Note #1 and Revision Note #2 at chapter heading for Env-Wq 900) #12364, eff 9-1-17