N.H. Code Admin. R. Env-Wq 711.04
(b) In lieu of (a), above, activated sludge settling tanks treating domestic wastes may be sized according to Table 711-1 below, wherein overflow rates are based on solids flux with a factor of safety of 1.3 against settling tank failure, overflow rates for systems with a selector are based on settling characteristics typical of mixed liquor with a sludge volume index (SVI) of 150 mL/g, and overflow rates for systems without selectors are based on settling characteristics typical of a mixed liquor with a SVI of 200 mL/g:
Table 711-1: Secondary Settling Tank Overflow Rates Peak Hourly Flow
MLSS, mg/L
Surface Overflow Rates at Critical Loading with SVI = 150 mL/g, gpd/sf
Surface Overflow Rates at Critical Loading with SVI = 250 mL/g, gpd/sf
1,500
2,100
1,850
2,000
1,710
1,450
2,500
1,400
1,140
3,000
1,140
900
3,500
930
690
4,000
760
550
4,500
610
440
5,000
510
340
(c) Side water depth for secondary settling tanks shall be as follows:
Source. (See Revision Note at chapter heading for Env-Wq 700) #8590, eff 3-25-06; ss by #10693, eff 10-15-14; ss by #14258, eff 7-1-25, EXPIRES: 7-1-35