- (a) Each by-pass screen device shall have clear openings between bars from 1.0 to 1.75 inches wide.
- (b) Clearance between bars on coarse racks or screens preceding mechanically-cleaned screens may be greater than 1.75 inches.
(c) Manually-cleaned screens shall be:
- (1) Designed and installed to accommodate being cleaned;
- (2) Be placed on a screen slope of 30 to 45 degrees with the horizontal if for non-emergency use; and
- (3) Used only in by-pass channels.
- (d) Clear openings for mechanical screens other than by-pass screens and preliminary screens or racks shall be ½-inch or less to maximize removal of inert material.
- (e) For manually-cleaned bar screens, the screen chamber shall be designed to provide a velocity through the screen of one foot per second at an average rate of flow calculated from design average daily flow.
- (f) For mechanically cleaned screens, maximum velocities during wet weather periods shall not exceed 2.5 feet per second, calculated based on the vertical open cross-sectional area below the flow line.
- (g) The screen channel invert shall be 3 to 6 inches below the invert of the incoming sewers. To prevent jetting action, the length and construction of the screen channel shall provide for a reestablished hydraulic flow pattern following the drop in elevation.
(h) The capacity of all screening equipment shall be as follows:
- (1) If one unit is installed, the unit shall be sized to handle peak hourly design flow;
- (2) If multiple units are installed for flexibility of maintenance, the peak hourly design flow shall be handled by the remaining units with the largest unit out of service; and
- (3) To avoid excessive head loss and potential damage to very fine screens when very fine screens are installed, multiple stages of screens with progressively smaller openings shall be used.
- (i) Influent channels shall be equipped with gates to isolate each screening device. The channel preceding and following the screen shall be shaped to eliminate settling of solids.
- (j) Where a single mechanically-operated screening device is used, auxiliary manually-cleaned screens shall be provided. The design shall include provisions for automatic diversion of the entire sewage flow through the by-pass screen if the mechanical unit fails.
Source. (See Revision Note at chapter heading for Env-Wq 700) #8590, eff 3-25-06; ss by #10693, eff 10-15-14; ss by #14258, eff 7-1-25, EXPIRES: 7-1-35