- (a) Force mains shall be sized to yield a cleansing velocity of 3 feet per second or greater at design pumping rate.
- (b) Force mains shall be 4 inches or larger in nominal diameter except when used in conjunction with grinder pumps and necessary to achieve adequate cleansing velocity at design pumping rate.
- (c) To prevent air locking, force mains shall be provided with an automatic air relief valve at each high point, installed within a manhole structure that meets the design requirements of Env-Wq 704.12 through Env-Wq 704.17.
- (d) Force mains shall enter the gravity sewer system at the flow line of the receiving manhole.
(e) Force mains shall be provided with a drainage blow-off at each low point that:
- (1) Has a properly valved connection for a vacuum truck or other suitable containment device; and
- (2) Is installed within a manhole structure that meets the design requirements of Env-Wq 704.12 through Env-Wq 704.17, with sufficient space for handling the displaced waste without danger of pollution or health hazard.
- (f) Force mains pipe joints shall include mechanical joint restraint or thrust blocks made from inorganic, corrosion-resistant material at all bends, elbows, tees, and junctions. Heat fused high density polyethylene joints do not require mechanical restraint or thrust blocking.
- (g) Force mains shall be designed to withstand instantaneous hydrostatic pressures of at least 2.5 times the design total dynamic head or at least 100 psi, whichever is greater.