Plans shall depict or otherwise include the following:
- (a) The boundaries of the property on which the project will occur;
(b) For the area of activity and within 250 feet, the following:
- (1) All existing or proposed lot lines;
- (2) All existing and proposed impervious or otherwise disturbed surfaces, including but not limited to borrow areas, roadways, driveways, parking areas, sidewalks, roofs, and structures, provided that if the applicant does not have survey access to abutting properties or other access to survey information, the information for abutting properties shall be provided using aerial photographs; and
- (3) All areas of undisturbed cover that will remain undisturbed;
- (c) All areas on the property for which a permit under RSA 485-A:17, I, was or should have been obtained, with identification of the permit by number if a permit was obtained;
- (d) The location(s) and type(s) of all existing vegetative cover;
(e) All water features as applicable, including but not limited to:
- (1) The direction of water flow;
- (2) The maximum high-water mark and usual shorelines;
- (3) The reference line as defined by RSA 483-B;
- (4) The location of wetlands and surface waters and their banks, including perennial and intermittent streams, vernal pools, tidal buffer zones and designated prime wetlands as identified under RSA 482-A;
- (5) The limits of the 100-year floodplain; and
- (6) The 0.25-mile designated river limit as identified under RSA 483;
- (f) All drinking water supply well sources, whether private or public, with set-backs as specified in Env-Wq 1508.02;
- (g) Soil types from NRCS maps, site-specific soil mapping, or as determined by Env-Wq 1504.09(b)(4)d.;
- (h) A clear delineation of the total area to be disturbed, including proposed improvements or modifications;
- (i) Locations and details of proposed temporary methods for protecting water quality in accordance with Env-Wq 1505.05, including devices and timing of implementation for erosion, sediment, and runoff control, that are adequate to prevent violations of the SWQ standards;
- (j) A note requiring fugitive dust to be controlled in accordance with Env-A 1000;
- (k) A note requiring the project to meet the requirements and intent of RSA 430:51-57 and Agr 3800 relative to invasive species;
(l) Construction phasing and sequencing that meets the following:
- (1) Shows compliance with Env-Wq 1505.05, including but not limited to methods for limiting the length of time that soils remain unstabilized; and
- (2) Identifies which single family or duplex residential lots may begin construction prior to completion of the project, so as to comply with Env Wq 1503.12(b);
- (m) Proposed cold weather stabilization techniques in accordance with Env-Wq 1505.06, if applicable;
- (n) Details, including plan and elevation views, of proposed permanent methods for protecting water quality from degradation due to runoff in accordance with Env-Wq 1507, that are adequate to prevent violations of the SWQ standards;
- (o) A complete storm drainage system, including size, slope, and invert elevations of all pipes and culverts, and detention measures;
- (p) A note explaining the intended use of the site or, if the intended use is unknown at the time the permit is issued, a note indicating whether or not local zoning allows for high-load uses and acknowledging that if a high-load use is proposed, the property owner or permit holder shall submit a source control plan pursuant to Env-Wq 1504.08 for approval prior to the commencement of operations of a high-load use;
- (q) Roadway stations shown every 100 feet;
- (r) Plan date and if applicable, any revision dates;
- (s) If applicable, existing and proposed drainage easement boundaries and maintenance access easement boundaries for proposed methods for protecting water quality as described in Env-Wq 1507, together with a statement signed by the applicant as specified in Env-Wq 1503.10 that the deeds for all proposed easements will be recorded as required by Env-Wq 1504.07; and
- (t) If applicable, the locations of where the blasting is required or anticipated and the site-specific blasting best management practices based on Env-Wq 1510.
Source. #9343, eff 1-1-09; amd by #9817-A, eff 12-1-10 (formerly Env-Wq 1504.05); ss by #12342, eff 8-15-17; ss by #14472, eff 1-19-26, EXPIRES: 1-19-36