- (a) Inlets for spas shall be arranged so as to provide uniform circulation and uniform disinfectant residual.
- (b) A minimum of 2 inlets shall be provided for each spa, with inlets added as necessary to accommodate the designed flow rate.
- (c) Spa inlets shall be adjustable to allow for changes in direction of flow.
- (d) A minimum of 2 outlets shall be provided for each pump in the spa’s circulation system.
(e) The outlets shall be:
- (1) Separated by a minimum of 3 feet or located on 2 different planes;
- (2) Connected to a common pipe through a tee configuration located such that the drains are hydraulically balanced;
- (3) Provided with a cover that complies with ANSI/APSP/ICC-16, 2011, available as noted in Appendix B; and
- (4) Protected as required by the VGBA, available at https://uscode.house.gov/view.xhtml?path=/prelim@title15/chapter106&edition=prelim and its implementing regulations at 16 CFR § 1450, available at https://www.ecfr.gov/cgi-bin/text-idx?SID=1410c3f48d73aa2683c546eab89a43b5&mc=true&node=pt16.2.1450&rgn=div5.
- (f) Piping of the spa’s drain outlet shall be capable of handling 100% of the circulation.
- (g) Each pump shall be equipped with a vacuum and pressure gauge that is separate from the pressure gauge associated with the filter.
Source. (See Revision Note #1 at chapter heading for Env-Wq 1100) #8468, eff 11-1-05; ss by #10577, eff 5-1-14 (See Revision Note #2 at chapter heading for Env-Wq 1100); ss by #13198, eff 5-1-21 (see Revision Note #3 at chapter heading for Env-Wq 1100) (formerly Env-Wq 1107.03)