The information required by Env-Wq 1104.03(b) shall be as follows for each PBF at the establishment:
- (a) The operating volume of the PBF, in gallons;
- (b) The materials of construction for the PBF;
- (c) The shape of the PBF;
(d) The following depths and dimensions, measured in feet:
- (1) Depth from operational water level at the shallow end;
- (2) Depth from operational water level at the breakpoint between the shallow and deep end;
- (3) Maximum depth from operational water level;
- (4) Perimeter length and length(s) and width(s) of sides; and
- (5) For spas, the spa body dimensions and the dimensions of the spa foot-well;
- (e) Surface area, in square feet;
- (f) Bather load;
- (g) The most recent flow rate measured from the flow meter, in gallons per minute (GPM);
- (h) The turnover time in hours;
- (i) The number of water inlets on the wall and the number of water inlets on the floor;
- (j) Whether a gutter or perimeter overflow system or skimmers are used, and if skimmers are used, the number of skimmers;
(k) The following information on suction outlets:
- (1) The total number of submerged suction outlets;
- (2) The location of each suction outlet, such as on the pool floor or sidewall;
- (3) Whether the suction outlet cover or grate is VGBA approved;
- (4) Whether the outlets are direct suction or indirect suction, sometimes called gravity;
- (5) The date of most recent replacement of suction outlet cover; and
- (6) Whether there is a dedicated vacuum line;
(l) Information on pumps, as follows:
- (1) The type of pump and how many of each type there are;
- (2) The manufacturer and model of the pump;
- (3) The horsepower of the pump; and
- (4) The number of outlets per pump;
(m) Information on the filter system, as follows:
- (1) The type of filter and the number of each type;
- (2) The manufacturer and model of the filter; and
- (4) The total effective filter area, in square feet;
- (n) Whether entrapment avoidance devices are used and if so, whether it is a safety vacuum release system (SVRS) or automatic shut-off and the manufacturer and model of the device; and
(o) Information on the disinfection system, as follows:
- (1) Whether the primary disinfection is chlorination or bromination and the type of product used;
- (2) The delivery method for the disinfection;
- (3) The manufacturer and model of the disinfection unit;
- (4) If a salt disinfection system is used, provide the number of cells and confirm that the system incorporates an automated pH control system as required by Env-Wq 1109.08(d)(1) and provide the manufacturer and model of the controller;
- (5) Confirmation that the disinfection system is wired such that the chemical feed equipment cannot operate when circulation flow stops as required by Env-Wq 1109.08(g)(2); and
- (6) Whether there is supplemental water treatment, and if so the type of disinfection and the manufacturer and model of the unit.
Source. #13198, eff 5-1-21 (see Revision Note #3 at chapter heading for Env-Wq 1100)