- (a) The gravity grease interceptor shall be sized to have a minimum hydraulic detention time of 36 hours and minimum tank size of 500 gallons.
- (b) The outlet of the gravity grease interceptor shall be protected with a baffle that extends downward and terminates 6 to 12 inches from the inside bottom of the gravity grease interceptor.
(c) A gravity grease interceptor shall meet the requirements of:
- (1) Env-Wq 1010.03 relative to being water-tight, provided that “septic tank” shall be replaced with “gravity grease interceptor”; and
- (2) Env-Wq 1010.06 relative to design, provided that “septic tank” shall be replaced with “gravity grease interceptor”.
(d) All connections between a gravity grease interceptor and the pipes leading to and exiting from the tank shall be sealed with a watertight, flexible connector that:
- (1) Will accommodate normal movement of the tank without leaking or breaking; and
- (2) Is certified by the manufacturer or distributor as conforming to ASTM C1644.
- (e) Any precast concrete gravity grease interceptor shall be certified by its manufacturer or distributor as meeting the applicable requirements of ASTM C1613.
- (f) Fiber-reinforced polyester used for manufacturing gravity grease interceptors and components shall be certified by its manufacturer or distributor as meeting the applicable requirements of section 6 of IAPMO/ANSI Z1000.
- (g) Thermoplastic gravity grease interceptors and components shall be certified by its manufacturer or distributor as meeting the applicable requirements of section 7 of IAPMO/ANSI Z1000.
Source. (See Revision Notes #1 and #2 at chapter heading for Env-Wq 1000) #11184, eff 10-1-16; ss by #14486, eff 2-1-26, EXPIRES: 2-1-36 (formerly Env-Wq 1012.02)