- (a) Subject to (b) below, structures required to have a grease interceptor pursuant to Env-Wq 1012.01 shall have an external gravity grease interceptor that meets the design requirements of Env-Wq 1012.03.
(b) Structures required to have a grease interceptor per Env-Wq 1012.01 may use a hydromechanical grease interceptor designed and operated according to the state building code pursuant to RSA 155-A instead of a gravity grease interceptor, provided that the structure:
- (1) Does not have a mechanical dishwasher;
- (2) Does not have a deep fryer or grill;
- (3) Does not have an in-sink garbage grinder;
- (4) Uses paper service only;
- (5) Does not have dine-in seating and is take-out only;
- (6) Removes all fats, oils, and grease on cookware using paper towels that are disposed as solid waste; and
(7) Has flow that will be less than 150 gallons per day, as determined from:
- a. The unit flow tables in Env-Wq 1008.04; or
- b. Metered flows pursuant to Env-Wq 1008.04.
Source. #14486, eff 2-1-26, EXPIRES: 2-1-36