- (a) To receive approval to operate for an ISDS that is required by Env-Wq 1003.02(d) to be designed by a permitted designer who is also a licensed professional engineer (P.E.), the provisions of (b) through (d), below, shall be met.
(b) The installation of the ISDS components shall be inspected throughout the construction process by the permitted designer and P.E. whose stamp and seal appear on the approved plan or by an equivalently-qualified permitted designer and P.E, including the installation of each of the following:
- (1) The preparation of the basal area;
- (2) The components of and elevations associated with the bed bottom;
- (3) The EDA and EDA fill materials;
- (4) The septic tank;
- (5) Any sewer manholes; and
- (6) Any associated pipe materials and connections.
- (c) If the plans approved by the department identify specific inspection requirements, those requirements shall be the minimum necessary to comply with (b), above.
- (d) The applicant shall submit a written certification, which has been signed by and which bears the stamp and seal of the individual who inspected the system’s installation pursuant to (b), above, that the ISDS has been installed in accordance with the approved plans.
Source. (See Revision Notes #1 and #2 at chapter heading for Env-Wq 1000) #11184, eff 10-1-16; ss by #14486, eff 2-1-26, EXPIRES: 2-1-36 (formerly Env-Wq 1004.10)