- (a) The O/O of a PWS that is vulnerable to asbestos contamination due solely to corrosion of asbestos-cement pipe shall collect one sample at a tap served by asbestos-cement pipe under conditions where asbestos contamination is most likely to occur.
- (b) The O/O of a PWS that is vulnerable to asbestos contamination due solely to the potential for source water contamination shall monitor as for general regulated inorganics in accordance with Env-Dw 711.01 through Env-Dw 711.08.
- (c) The O/O of a PWS that is vulnerable to asbestos contamination both to corrosion of asbestos-cement pipe and the potential for source water contamination shall collect one sample at a tap served by asbestos-cement pipe under conditions where asbestos contamination is most likely to occur.
- (d) The department shall establish the sampling point in the sampling schedule established pursuant to Env-Dw 708.01 after conferring with the O/O relative to appropriate factors such as the amount of asbestos cement pipe and the age of the pipe.
Source. #9700, eff 5-1-10; ss by #12668, eff 1-1-19