The owner or operator of any stationary source, area source, or device with add-on VOC control equipment shall maintain records of the following information, as applicable:
- (a) The air pollution control device identification number, type, model number, and manufacturer;
- (b) Installation date;
- (c) Process(es) or device(s) controlled;
- (d) The type and location of the capture system, capture efficiency percentage, and method of determining capture efficiency;
- (e) Information as to whether or not the control device is always in operation when the process(es) or device(s) are in operation;
(f) The destruction or removal efficiency of the add-on air pollution control equipment, including:
- (1) Destruction or removal efficiency, in percent;
- (2) Date tested;
(3) The emission test results, if tested, including:
- a. The inlet VOC concentration in ppm;
- b. The outlet VOC concentration in ppm; and
- c. The method of determination of the concentrations in a. and b. above; and
- (4) The method of determining destruction or removal efficiency, if not tested;
- (g) For thermal incinerators, the design combustion temperature in degrees F;
(h) For catalytic incinerators:
- (1) The design exhaust gas temperature in degrees F;
- (2) The design temperature rise across the catalyst bed in degrees F;
- (3) The anticipated frequency of catalyst change; and
- (4) Any actual catalyst changes;
(i) For a condenser:
- (1) The design inlet temperature of the cooling medium; and
- (2) The design exhaust gas temperature in degrees F; and
(j) For a carbon adsorber:
- (1) The design pressure drop across the adsorber; and
- (2) The VOC concentration at breakthrough.
Source. #10892, eff 7-18-15 (from Env-A 904.07); ss by #14374, eff 9-20-25, EXPIRES: 9-20-35 (formerly Env-A 904.08)