For all industrial adhesives, surface coating, and printing operations that are subject to Env-A 1200, the owner or operator shall maintain records of the following information:
(a) Except those sources subject to Env-A 1215.01 through Env-A 1215.04 and Env-A 1216, adhesive, coating, or ink formulation, and analytical data, as follows:
- (1) Supplier;
- (2) Name and color;
- (3) Type;
- (4) Identification number;
- (5) Density described as lbs/gal;
- (6) Total volatile content described as weight percent;
- (7) Water content described as weight percent;
- (8) Exempt solvent content described as weight percent;
- (9) VOC content described as weight percent;
- (10) Solids content described as volume percent;
- (11) Diluent name and identification number;
- (12) Diluent solvent density described as lbs/gal;
- (13) Diluent VOC content described as weight percent;
- (14) Diluent exempt solvent content described as weight percent;
- (15) Volume of diluent VOC described as gal; and
- (16) Diluent solvent ratio described as gal diluent solvent/gal coating;
- (b) The number of gallons of each coating and ink, including solvents and diluents, used during a typical high ozone season day;
(c) Process information for a typical high ozone season day including:
- (1) Method of application;
- (2) Number of coats for coating operations;
- (3) Drying method, if applicable; and
- (4) Substrate type and form;
(d) For printing operations subject to Env-A 1215.01 through Env-A 1215.04, ink formulation as follows:
- (1) Volume percent of VOC as applied;
- (2) Volume percent of VOC and water for the volatile fraction of the ink; or
- (3) For packaging rotogravure and flexographic printing only, pounds VOC per pound of solids or kilograms VOC per kilogram of solids as applied; and
(e) For printing operations subject to Env-A 1216, cleaning material and fountain solution information as follows:
- (1) Amount of cleaning materials used on a monthly basis, in gallons or pounds for each cleaning material that does not meet either of the requirements in Env-A 1216(a)(1) or (a)(2);
- (2) VOC content described as weight percent or in terms of pounds of VOC per gallon of cleaning solution as applied, if applicable;
- (3) If fountain solution is refrigerated, the temperature of the solution; and
- (4) Documentation of the alcohol content of fountain solutions.
Source. #6983-B, eff 4-23-99 (formerly Env-A 901.06); ss by #8872, eff 4-21-07; ss by #10892, eff 7-18-15; ss by #12043, eff 11-18-16; ss by #14374, eff 9-20-25, EXPIRES: 9-20-35