- (a) Owners or operators of stationary sources subject to Env-A 1300, with the exception of those devices specified in Env-A 803.05, those sources whose owners or operators opted out of the NOx RACT regulation in accordance with Env-A 1301.02(m), and those sources with a NOx continuous emission monitoring system certified, operated, and maintained in accordance with Env-A 808, shall conduct periodic compliance stack testing in accordance with Env-A 802 to demonstrate compliance with the applicable NOx RACT air pollution control requirements specified in Env-A 1303 through Env-A 1313.
- (b) The periodic compliance stack testing required by (a), above, shall be conducted at least once every 3 years, or within 12 calendar quarters, after the date of the initial compliance stack test.
Source. (See Revision Note at chapter heading for Env-A 800) #5505 eff 11-15-92; ss by #6087, eff 8-31-95; ss by #7788, eff 10-31-02; ss by #8234, eff 12-22-04; ss by #9802, eff 10-31-10; ss by #12762, eff 5-1-19