N.H. Code Admin. R. Env-A 4303.01
(a) Subject to (b), below, the emission limits for existing OSWI units shall be as specified in Table 4303-1, below, for the listed air pollutants or parameters and all OSWI technologies:
Table 4303-1: Emission Limits for All Existing OSWI Units
Pollutant/Parameter
Emission Limits a
Averaging Time
Compliance Determination b, c
Cadmium (Cd)
18 micrograms per dry standard cubic meter (μg/dscm)
3-run average (1 hour minimum sample run time)
EPA Method 29
Carbon Monoxide (CO)
40 parts per million dry volume (ppmdv)
3-run average (1 hour minimum sample run time), and 12-hour rolling averages measured using CEMS
EPA Methods 10, 10A or 10B
Dioxins/Furans, total mass basis
33 nanograms per dry standard cubic meter (ng/dscm)
3-run average (1 hour minimum sample run time)
EPA Method 23
Hydrogen Chloride (HCl)
15 ppmdv
3-run average (1 hour minimum sample run time)
EPA Method 26A
Lead (Pb)
226 μg/dscm
3-run average (1 hour minimum sample run time)
EPA Method 29
Mercury (Hg)
74 μg/dscm
3-run average (1 hour minimum sample run time)
EPA Method 29
Opacity
10 percent
6-minute average (observe over three 1-hour test runs)
EPA Method 9
Oxides of Nitrogen (NOx)
103 ppmdv
3-run average (1 hour minimum sample run time)
EPA Methods 7, 7A, 7C, 7D or 7E d
Particulate Matter (PM)
0.013 grains per dry standard cubic foot (gr/dscf)
3-run average (1 hour minimum sample run time)
EPA Methods 5 or 29
Sulfur Dioxide (SO2)
3.1 ppmdv
3-run average (1 hour minimum sample run time)
EPA Method 6 or 6C e
(b) The following notes shall apply to Table 4303-1:
Source. #8787, eff 1-5-07; ss by #10765, eff 1-22-15; ss by #14248, eff 5-20-25, EXPIRES: 5-20-35