N.H. Code Admin. R. Env-A 3505.02
(c) The emission limits for small, medium, and large HMIWI shall be as set forth in Table 3500-2 below, based on 7 percent oxygen, dry basis:
TABLE 3500-2: EMISSION LIMITS FOR SMALL, MEDIUM, AND LARGE HMIWI
Pollutant
Units
Emission limits
HMIWI size
Small
Medium
Large
Particulate matter
milligrams per dry standard cubic meter; or
grains per dry standard cubic foot
115
0.05
69
0.03
34
0.015
Carbon monoxide
parts per million by volume
40
40
40
Dioxins/furans
If measured as total dioxins/furans, either:
nanograms per dry standard cubic meter total dioxins/furans; or
grains per billion dry standard cubic feet total dioxins/furans.
If measured as toxic equivalency (TEQ), either:
nanograms per dry standard cubic meter TEQ; or
grains per billion dry standards cubic feet TEQ.
125
55
2.3
1.0
125
55
2.3
1.0
125
55
2.3
1.0
Hydrogen chloride
parts per million by volume; or
percent reduction
100
93%
100
93%
100
93%
Sulfur dioxide
parts per million by volume
55
55
55
Nitrogen oxides
parts per million by volume
250
250
250
Lead
milligrams per dry standard cubic meter;
grains per thousand dry standard cubic feet; or
percent reduction
1.2
0.52
70%
1.2
0.52
70%
1.2
0.52
70%
Cadmium
milligrams per dry standard cubic meter;
grains per thousand dry standard cubic feet; or
percent reduction
0.16
0.07
65%
0.16
0.07
65%
0.16
0.07
65%
Mercury
milligrams per dry standard cubic meter; or
grains per thousand dry standard cubic feet;
0.055
0.024
0.055
0.024
0.055
0.024
Source. #6938, eff 1-30-99; amd by #7127, eff 10-30-99; ss by #8788, eff 1-5-07