N.H. Code Admin. R. Env-A 2102.04
(a) Where the process weight rate is not explicitly listed in Table 2102-1, the maximum allowable particulate matter emission rate shall be calculated using the applicable equation in (b) or (c), below, where:
(b) For a stationary source or device installed prior to or on February 18, 1972, if the process weight rate is:
(1) Up to 30 tons/hr, P shall be raised to the 0.67 power and multiplied by 5.05, as shown in the formula below:
E = 5.05 P0.67
(2) In excess of 30 tons/hr, P shall be raised to the 0.11 power and multiplied by 66.0, and then 48 shall be subtracted from that result, as shown in the formula below:
E = 66.0 P0.11 - 48
(c) For a stationary source or device installed after February 18, 1972, if the process weight rate is:
(1) Up to 30 tons/hr, P shall be raised to the 0.67 power and multiplied by 4.10, as in the formula below:
E = 4.10 P0.67
(2) In excess of 30 tons/hr, P shall be raised to the 0.11 power and multiplied by 55.0, and then 40 shall be subtracted from that result, as in the formula below:
E = 55.0 P0.11 - 40
Source. #8215, eff 11-24-04 (from Env-A 2103); ss by #10314, eff 4-23-13; ss by #13693, eff 7-22-23