N.H. Code Admin. R. Env-A 1404.04
If the in-stack concentration method is selected, the owner or operator shall use the following equations to calculate that the emissions of each RTAP is equal to or below the corresponding AAL, where:
(a) “X” means:
(b) “Y” means the emission rate of each RTAP in grams per second (g/sec) as determined by dividing X by 7.94, as shown in the formula below:
Y (g/sec) = X (lbs/hr) / 7.94
(c) “Z” means the emission rate of each RTAP in micrograms per second (μg/sec) as determined by multiplying Y by 106, as shown in the formula below:
Z (μg/sec) = Y (g/sec) x 106
(d) “A” means:
(e) “B” means the stack volume flow in actual cubic meters per second (m3/sec) as determined by dividing A by 2119, as shown in the formula below:
B (m3/sec) = A (ft3/min) / 2119
(f) The in-stack concentration of each RTAP in micrograms per cubic meter (μg/m3) from a device or process either emitting from a single stack or from more than one stack shall be calculated by dividing Z by B, as shown in the formula below:
In-stack Concentration (μg/m3) = Z (μg/sec) / B (m3/sec)
Source. #8278, eff 2-4-05 (from Env-A 1406.04); ss by #9601, eff 11-25-09; ss by #12443, eff 1-5-18; ss by #13334, eff 2-3-22 (formerly Env-A 1405.04)