When a new scale is installed, the scale shall be tested as follows:
(a) Scales shall be tested with certified test weights in accordance with the appropriate sections of the following documents:
- (1) NIST Handbook 44 "Specifications, Tolerances, and other Technical Requirements for Weighing and Measuring Devices"; and
- (2) NIST Handbook 112 "Examination Procedure Outlines for Commercial Weighing and Measuring Devices," 2002 edition as amended.
(b) When conducting a substitution test on a weighing device, service technicians shall:
- (1) Apply known test weight(s) to the load-receiving element as outlined in NIST Handbook 44, NIST Handbook 112 or both;
- (2) Remove the known test weight(s) and apply to the load-receiving element an unknown weight or weights not exceeding the amount of known test weight(s) first applied to the load-receiving element of the scale; and
- (3) Repeat the process described in (2) above until the scale has been tested to its capacity.
Source. (See Revision Notes #1 and #2 at chapter heading for Agr 1400) #12424, eff 12-1-17