15A NCAC 18E .1205
(c) If a groundwater lowering system is used to comply with the vertical separation to a SWC, the following conditions shall apply:
(d) Table XXXI shall be used to determine the LTAR for a sand-lined trench system and shall be based on the most limiting, naturally occurring soils overlying the permeable receiving layer. An equivalent trench width of three feet shall be used to determine trench length in accordance with Rule .0901(d) of this Subchapter. The LTAR shall be one of the following:
(2) 20 percent of the in-situ Ksat of the receiving permeable horizon, whichever is less.
TABLE XXXI. LTAR for advanced pretreatment sand lined systems based on texture of the most hydraulically limiting overlying soil horizon
* Trench length for trench dispersal products approved with a specific dispersal field reduction in area or trench length when receiving DSE effluent in accordance with this Subchapter or a PIA approval shall be calculated in accordance with this Subchapter or the PIA approval.
(e) A Special Site Evaluation in accordance with Rule .0510 of this Subchapter shall be required for the following conditions to field verify the LTAR:
History Note: Authority G.S. 130A-334; 130A-335; 130A-342; 130A-343; S.L. 2024-49, s.4.38;
Eff. January 1, 2024;
Amended Eff. June 1, 2026.