- (1) Cattle guards and cattle chutes (see ARM 38.4.411 (4) and (5) .)
- (2) Hand rails on bridges and trestles (see ARM 38.4.411(4) .)
- (3) Switch boxes, switch operating mechanism necessary for the control and operation of signals and interlockers projecting four (4) inches or less above the top of the rail require a minimum clearance of three (3) feet.
- (4) Mail cranes and train order stands when not in operative position require a minimum clearance of eight (8) feet six (6) inches.
- (5) Oil columns require a minimum clearance of eight (8) feet (see ARM 38.4.411(4) and (5) .)
- (6) Poles supporting trolley contact require a minimum clearance of eight (8) feet three (3) inches. Conductors supplying motive power to track affected--of bracket construction.
- (7) Poles other than trolley poles require a minimum clearance of eight (8) feet six (6) inches.
- (8) Signals and switch stands three (3) feet high or less when located between tracks where not practicable to provide clearances otherwise prescribed in this order require a minimum clearance of six (6) feet.
- (9) Signals and switch stands other than in (8) above require a minimum clearance of eight (8) feet.
- (10) Water barrels on bridges (see ARM 38.4.411(4) an (5) .)
- (11) Water columns require a minimum clearance of eight (8) feet (see ARM 38.4.411(4) and (5) .)
Authorizing statute(s): Sec. 69-14-116, MCA
Implementing statute(s): Sec. 69-14-116, MCA
History: NEW, 1978 MAR p. 1485, Eff. 10/27/78.