The following standards are advisory, rather than mandatory:
- (1) Sources of illumination, both natural and artificial, should be provided with light diffusion means, or should be of a type and design which limits excessive glare.
(2) The following minimum lighting, measured in foot-candles, should be maintained during all periods of use:
- (a) hallways, corridors, storerooms, locker rooms, shower rooms, auditoriums (not for study) -- 10;
- (b) cafeterias, reception rooms, swimming rooms, gymnasiums, toilet rooms, laundry rooms -- 20;
- (c) classrooms, study halls, lecture rooms, art rooms, libraries -- 50;
- (3) In shops, laboratories, drafting rooms, typing rooms, home economics rooms, or other areas where pupils use specific machines or equipment, a minimum of 100 footcandles should be maintained on such machinery or equipment while in use.
Authorizing statute(s): 50-1-206, MCA
Implementing statute(s): 50-1-203, 50-1-206, MCA
History: NEW, 1986 MAR p. 546, Eff. 4/11/86; TRANS, from DHES, 2001 MAR p. 2425.