Beginning on November 15, 2002, owners and operators decommissioning a holding tank shall:
(1) For Above-ground Holding Tanks:
- (a) pump and haul away the entire contents of the tank; and
- (b) clean the holding tank and related areas as necessary.
(2) For In-ground Holding Tanks:
- (a) pump and haul away the entire contents of the tank;
- (b) clean the holding tank and related areas as necessary;
(c) decommission the in-ground holding tank with one of the following options:
- 1. remove the holding tank from the ground; or
- 2. fill the holding tank with clean sand, soil, or other inert material; or
- 3. change the function of the holding tank permanently;
(d) notify the Department in writing within 30 days of decommissioning with the following information:
- 1. the name and address of the facility, the name of the owner or operator;
- 2. the date of holding tank decommissioning;
- 3. the most recent shipment record as specified in 314 CMR 18.09(1)(b); and
- 4. a brief description of how the holding tank was decommissioned.