310 C.M.R. 7.06
(1) U Stationary Sources Other than Incinerators.
(c) Exception.
1. Visible Emission Limits. In lieu of the requirements of 310 CMR 7.06(1)(a) and 310 CMR 7.06(1)(b), a facility subject to 310 CMR 7.00: Appendix C - Operating Permits with boilers rated less than 500 million Btu per hour energy input capacity, may elect to comply with the following:
c. For a boiler equipped with a visible emission monitor with a numeric data reduction system that can printout individual block averages or output individual block averages to an electronic file, the Department will make a determination to approve or deny visible emissions during periods of startup, shutdown, soot blowing and other specified operating conditions to exceed 27% opacity for one-tenth of one percent of the total six-minute block averages during any calendar quarter, or six block averages per boiler per quarter, whichever is greater, provided visible emissions do not exceed 60% opacity during any six-minute block average.
d. Compliance with visible emission limits shall be based upon a six-minute block average determined either
2. Plan of Good Operating Practices. The plan of good operating practices shall, at a minimum:
3. Department Action.
(2) From Incinerators.
(5) From Spark-ignited Internal Combustion Engines.
(a) No person shall cause, suffer, allow, or permit emission of visible air contaminants, other than water, from internal combustion engines of: