Syringes, needles, lancets, or other blood-letting devices capable of transmitting infection from one person to another shall not be reused unless they are properly sterilized prior to each use and wrapped in a manner which will insure that they remain sterile until used.
- (A) Appropriate sterilization and disinfection techniques shall be utilized, as required, for tests performed on potentially contaminated material and for the protection of laboratory personnel.
- (B) Disposable syringes, needles, pipettes, petri dishes, and other disposable items shall be appropriately discarded immediately after use.
- (C) Records shallbe kept which indicate that each sterilizing cycle contains a device which indicates proper sterilization was carried out.
- (D) Proper operation of the autoclave shall be checked monthly with viable spores or appropriate indicators.