KRS 318.130 requires the department to promulgate administrative regulations establishing the Kentucky State Plumbing Code to regulate plumbing, including the sizes of waste piping. This administrative regulation establishes the minimum size of waste piping required for certain fixtures.
- Section 1. The minimum size (nominal inside diameter) of traps, soil, or waste branches for a given fixture shall not be less than that established in the following table: Minimum Size (in inches)Fixture UnitTrapBranchAutomatic clothes washer222Basement floor drain333Bath: sitz1 1/21 1/22Bathtub1 1/21 1/21 1/2Combination fixture222Dental cuspidor222Dishwasher1 1/21 1/21 1/2Disposal unit1 1/21 1/21 1/2Drinking fountain1 1/41 1/41Floor drain in residential laundry room222Floor drain in toilet room333Floor drain in utility room333Industrial floor drain444Kitchen sink unit1 1/21 1/21 1/2Laundry tray1 1/21 1/21 1/2Lavatories1 1/41 1/41Santistand346Shower stall1 1/21 1/21 1/2Sink: bar or soda fountain1 1/21 1/21 1/2Sink: barium222Sink: chemical1 1/21 1/21 1/2Sink: clinic346Sink: kitchen, residence1 1/21 1/21 1/2Sink: plaster222Sink: service333Sink: service wall type222Sink: three compartment222Urinal: lip1 1/21 1/21 1/2Urinal: pedestal333Urinal: stall222Urinal: trough1 1/21 1/21 1/2Water closet: Greater than 1.6 gallons per flush33 or 46Water closet: 1.6 gallons per flush or less33 or 44
History
(1 Ky.R. 481; eff. 3-12-1975; Recodified from 401 KAR 1:050, 7-5-78; Am. 9 Ky.R. 47; eff. 8-11-1982; TAm eff. 8-9-2007; 43 Ky.R. 460; eff. 11-16-2016; 46 Ky.R. 1667; eff. 6-2-2020.)