Kan. Admin. Regs. § 82-3-709
This regulation shall apply only within the boundaries of groundwater management districts #2 and #5. Each operator, owner, or person responsible shall ensure that the requirements of this regulation are met. (a) The construction features of each uncased cathodic protection borehole shall prevent physical damage to the installation and prevent the entry of pollutants and contaminants into fresh and usable groundwater.
(b) Each uncased borehole shall be grouted from the top of the anode conductor grout to three feet below land surface with either of the following:
(e) In any area having a saline concentration of 500 ppm or higher, or as determined by the manager of the appropriate GMD office after consideration of ambient water quality data taken from the area within a ½-mile radius of the proposed uncased borehole, a log of a test well located within 20 feet of the proposed uncased borehole shall accompany each uncased cathodic borehole application submitted pursuant to K.A.R. 82-3-705 and shall include the following information:
(5) the analyses of groundwater samples collected in a manner approved by the manager of the appropriate GMD office from the upper, middle, and lower portions of an aquifer. These analyses shall meet the following requirements:
(Authorized by K.S.A. 55-152 and K.S.A. 2003 Supp. 82a-1028; implementing K.S.A. 55-152, K.S.A. 2003 Supp. 55-164, and K.S.A. 2003 Supp. 82a-1028; effective, T-82-1-21-04, Jan. 21, 2004; effective May 14, 2004.)