Sec. 3. (a) The soil or foundation of an earthen storage structure shall have a maximum specific discharge permeability of one-sixteenth (1/16) in3/in2/day, 1.8x10-6cm3/cm2/sec. This requirement may be satisfied by soil testing that shows a minimum of three (3) feet of in situ soils that:
(b) If there is not at least three (3) feet of in situ soils that meet the maximum specific discharge criteria in subsection (a), a liner must be used. Except for clay liners described in subsection (c), liners used in a storage structure must meet the following design standards as applicable:
(c) Clay liners shall be a minimum of one (1) foot thick and have a maximum specific discharge of one-sixteenth (1/16) in3/in2/day, 1.8x10-6cm3/cm2/sec.
*These documents are incorporated by reference. Copies may be obtained from the Indiana NRCS State Office, 6013 Lakeside Boulevard, Indianapolis, IN 46278 or are available for review and copying at the Indiana Department of Environmental Management, Office of Legal Counsel, Indiana Government Center North, Thirteenth Floor, 100 North Senate Avenue, Indianapolis, Indiana 46204.