Ind. Admin. Code tit. 329, r. 10-17-2
Authority: IC 13-14-8-7; IC 13-15; IC 13-19-3
Affected: IC 13-20; IC 36-9-30
Sec. 2. (a) The following liner design is required for any section of a new MSWLF unit within an MSWLF or lateral expansion to be permitted under this article that will not be located over an aquifer of significance, as defined under 329 IAC 10-2-13, or will be located over an aquifer of significance, but there is a continuous layer of at least ten (10) feet of nonaquifer material, as defined under 329 IAC 10-2-120, separating the base of the proposed soil liner and the uppermost portion of the aquifer:
(1) At the base and side slopes, starting from the subgrade and extending upward, the liner must include the following components:
(2) At all sump areas, at a minimum, the liner must extend ten (10) feet from the outermost edge of the designated sump boundary on all sides. Starting from the subgrade and extending upward, the liner must include the following components:
(b) The following liner design is required for any section of a new MSWLF unit or lateral expansion within an MSWLF to be permitted under this article that will be located over an aquifer of significance, as defined under 329 IAC 10-2-13, and there is not a continuous layer of at least ten (10) feet of nonaquifer material, as defined under 329 IAC 10-2-120, separating the base of the proposed soil liner and the uppermost portion of the aquifer:
(1) At the base and side slopes, starting from the subgrade and extending upward, the liner must include the following components:
(c) For the purposes of this rule, sump areas are considered to be those areas of the proposed MSWLF unit that are designed to collect and remove leachate where leachate is expected to accumulate to a depth of at least one (1) foot.
(d) The minimum distance for extension of liner design components related to sump areas may be increased at the discretion of the commissioner, depending on site-specific factors, with consideration of the highest temporal fluctuations of the ground water table at the site.
(e) The commissioner may make available to the applicant standardized municipal solid waste landfill designs that are not less stringent than the requirements of this rule.
(Solid Waste Management Division; 329 IAC 10-17-2; filed Mar 14, 1996, 5:00 p.m.: 19 IR 1831; filed Mar 19, 1998, 11:07 a.m.: 21 IR 2774; filed Aug 2, 1999, 11:50 a.m.: 22 IR 3813; filed Feb 9, 2004, 4:51 p.m.: 27 IR 1814, eff Apr 1, 2004; readopted filed Oct 16, 2024, 11:58 a.m.: 20241113-IR-329230812RFA)