Authority: IC 13-14-8-7; IC 13-15; IC 13-19-3
Affected: IC 13-18; IC 13-20; IC 36-9-30
Sec. 3. (a) A permit application for a new MSWLF or a lateral expansion must be accompanied by a minimum of two (2) intersecting cross-sectional drawings. The drawings must include the following:
- (1) Elevations that correlate with USGS mean sea level data.
(2) Final construction plan with:
- (A) horizontal and vertical solid waste boundaries;
- (B) drainage structures;
- (C) leachate collection system;
- (D) explosive gas management system components;
- (E) proposed depth of the excavation; and
- (F) other significant features that may adversely affect the facility design.
(b) In addition to the two (2) cross-sectional drawings required in subsection (a), a permit application for a new MSWLF or a lateral expansion must be accompanied by a minimum of two (2) geological cross-sections. The two (2) geological cross-sections must intersect, and the locations of the sections indicated on the existing feature plan or the piezometric contour map. Each geologic cross-sectional drawing must have horizontal and vertical bar scales and depict the following:
- (1) The types of soil materials or rock strata, as identified by boring logs, from the ground surface to the required boring depth.
- (2) Present topography (mean sea level elevations).
- (3) Uppermost aquifer and all significant zones of saturation.
- (4) Any vertical components of ground water flow based on information contained in the hydrogeologic site investigation report for the uppermost aquifer and all significant zones of saturation.
- (5) All boring locations along the transect used to prepare the cross section.
- (6) Proposed horizontal solid waste boundary.
- (7) The base of the liner system or if required any leak detection system and the top of the protective system.
- (8) Direction of cross-sectional traverse.
- (9) Proposed depth of excavation if it differs from that in subdivision (7).
- (10) The original grade, if available.
(c) A permit application for a new MSWLF or a lateral expansion must be accompanied by detail drawings that are cross-sectional of the:
- (1) liner system;
- (2) geosynthetic anchor trenches if applicable;
- (3) final cover system;
- (4) drainage structures;
- (5) permanent sedimentation and erosion control structures;
(6) leachate collection system, including:
- (A) subgrade elevation;
- (B) piping;
- (C) cleanout location;
- (D) drainage features and structures;
- (E) sump, risers, and manholes; and
- (F) lift station elevations if applicable;
- (7) explosive gas monitoring and management system;
- (8) on-site roads;
- (9) monitoring well construction; and
- (10) any other site specific construction details that may adversely affect the facility plan.
(Solid Waste Management Division; 329 IAC 10-15-3; filed Mar 14, 1996, 5:00 p.m.: 19 IR 1819; filed Mar 19, 1998, 11:07 a.m.: 21 IR 2760; filed Aug 2, 1999, 11:50 a.m.: 22 IR 3798; readopted filed Oct 16, 2024, 11:58 a.m.: 20241113-IR-329230812RFA)