Sec. 11. The permit application for a new MSWLF or a lateral expansion must be accompanied by a leachate contingency plan. At a minimum, the following items must be addressed:
- (1) A list and description of the procedures to be used to monitor the leachate level in the sump area, manhole, or vertical riser.
- (2) A list and description of the procedures to be used for routine maintenance. The routine maintenance may be daily, weekly, quarterly, or annually, as applicable.
(3) A list and description of the expected potential cause of leachate level exceedance. Potential cause may include the following:
- (A) Temporary shut down of pretreatment.
- (B) Loss of authorization of discharge leachate to the treatment plant.
- (C) Blockage in the leachate collection or leachate removal system.
- (D) An inoperable sump pump.
- (E) Heavy rainfall.
- (F) Natural disasters.
- (4) Describe the corrective measure that will be implemented when the leachate level is exceeded.