Ind. Admin. Code tit. 326, r. 8-14-3
Authority: IC 13-14-8; IC 13-17-3-4
Affected: IC 13-17
Sec. 3. (a) Except as provided in subsections (c) and (d), on or after October 1, 2011, no person shall:
any AIM coating with a VOC content in excess of the corresponding limit specified in subsection (b).
(b) Compliance with the VOC content limits shall not exceed the following limits:
| Coating Category | VOC Limit (grams/liter) | VOC Limit (pounds/gallon) |
|---|---|---|
| Flat coatings | 100 | 0.835 |
| Nonflat coatings | 150 | 1.25 |
| Nonflat-high-gloss coatings | 250 | 2.09 |
| Specialty coatings: | ||
| Antenna coatings | 530 | 4.42 |
| Antifouling coatings | 400 | 3.34 |
| Bituminous roof coatings | 300 | 2.50 |
| Bituminous roof primers | 350 | 2.92 |
| Bond breakers | 350 | 2.92 |
| Calcimine recoaters | 475 | 3.96 |
| Clear wood coatings: | ||
| Clear brushing lacquers | 680 | 5.67 |
| Lacquers, including clear lacquer sanding sealers | 550 | 4.59 |
| Sanding sealers, excluding clear lacquers | 350 | 2.92 |
| Varnishes other than conversion varnishes | 350 | 2.92 |
| Conjugated oil varnish | 450 | 3.76 |
| Conversion varnish | 725 | 6.05 |
| Concrete curing compounds | 350 | 2.92 |
| Concrete surface retarders | 780 | 6.51 |
| Dry fog coatings | 400 | 3.34 |
| Faux finishing coatings | 350 | 2.92 |
| Fire-resistive coatings | 350 | 2.92 |
| Fire-retardant coatings (clear) | 650 | 5.42 |
| Fire-retardant coatings (opaque) | 350 | 2.92 |
| Floor coatings | 250 | 2.09 |
| Flow coatings | 420 | 3.51 |
| Form-release compounds | 250 | 2.09 |
| Graphic arts coatings (sign paints) | 500 | 4.17 |
| High temperature coatings | 420 | 3.51 |
| Impacted immersion coatings | 780 | 6.51 |
| Industrial maintenance coatings | 340 | 2.84 |
| Low-solids coatings | 120 | 1.00 |
| Magnesite cement coatings | 450 | 3.76 |
| Mastic texture coatings | 300 | 2.50 |
| Metallic pigmented coatings | 500 | 4.17 |
| Multicolor coatings | 250 | 2.09 |
| Nuclear coatings | 450 | 3.76 |
| Pretreatment wash primers | 420 | 3.51 |
| Primers, sealers, and undercoaters | 200 | 1.67 |
| Quick-dry enamels | 250 | 2.09 |
| Quick-dry primers, sealers, and undercoaters | 200 | 1.67 |
| Recycled coatings | 250 | 2.09 |
| Roof coatings | 250 | 2.09 |
| Rust preventive coatings | 400 | 3.34 |
| Shellacs (clear) | 730 | 6.09 |
| Shellacs (opaque) | 550 | 4.59 |
| Specialty primers, sealers, and undercoaters | 350 | 2.92 |
| Stains | 250 | 2.09 |
| Stone consolidants | 450 | 3.76 |
| Swimming pool coatings | 340 | 2.84 |
| Swimming pool repair and maintenance coatings | 340 | 2.84 |
| Temperature-indicator safety coatings | 550 | 4.59 |
| Thermoplastic rubber coatings and mastics | 550 | 4.59 |
| Traffic marking coatings (ozone season-May 1 to September 30) | 105 | 0.876 |
| Traffic marking coatings (nonozone season- October 1 to April 30) | 150 | 1.25 |
| Waterproofing sealers | 250 | 2.09 |
| Waterproofing concrete or masonry sealers | 400 | 3.34 |
| Wood preservatives | 350 | 2.92 |
| Conversion factor: one gram VOC per liter = 0.0083454 pound per gallon. | ||
(c) If anywhere on the container of an AIM coating, or any label or sticker affixed to the container, or in any sales, advertising, or technical literature supplied by a manufacturer or anyone acting on their behalf, any representation is made that indicates that the coating meets the definition or is recommended for use for more than one (1) of the categories listed in subsection (b), then the category with the most restrictive VOC content limit shall apply. This provision does not apply to the coating categories specified as follows:
(d) The following sell through provisions apply to AIM coatings:
(e) The following work practices are required:
(1) All AIM coatings containers used to apply the contents therein to a surface directly from the container by:
(f) No person who applies or solicits the application of any AIM coating shall apply a coating that is thinned to exceed the applicable VOC limit specified in subsection (b).
(g) No person shall apply or solicit the application of any rust preventative coating for industrial use, unless the rust preventative coating complies with the industrial maintenance coating VOC content limit specified in subsection (b).
(h) If a coating does not meet any of the definitions for the specialty coatings categories listed in subsection (b), the VOC content limit shall be determined by classifying the coating as a flat coating, nonflat coating, or nonflat-high-gloss coating as defined in section 2 of this rule. The corresponding flat or nonflat coating VOC content limit shall apply.
(Air Pollution Control Division; 326 IAC 8-14-3; filed Nov 1, 2010, 11:58 a.m.: 20101201-IR-326060604FRA; readopted filed Oct 18, 2024, 2:09 p.m.: 20241113-IR-326230809RFA)