Ind. Admin. Code tit. 326, r. 20-13.1-12
Authority: IC 13-14-8; IC 13-17-3-4; IC 13-17-3-11
Sec. 12. (a) The owner or operator of a secondary lead smelter shall use the following test methods to determine compliance with the emission standards for lead compounds:
(b) The owner or operator of a secondary lead smelter shall use the following test methods to determine compliance with the emission standards for total hydrocarbons:
(c) The owner or operator of a secondary lead smelter shall correct the measured total hydrocarbon concentrations to four percent (4%) carbon dioxide, specified as follows:
(1) If the measured percent carbon dioxide is greater than four-tenths of one percent (0.4%) in each compliance test, the owner or operator of a secondary lead smelter shall determine the correction factor using the following equation: 
| Where: | F | = | Correction factor (no units). |
|---|---|---|---|
| CO2 | = | Percent carbon dioxide measured using 40 CFR 60, Appendix A-2, Method 3A* or 40 CFR 60, Appendix A-2, Method 3B*, where the measured carbon dioxide is greater than four-tenths of one percent (0.4%). |
(d) The owner or operator of a secondary lead smelter shall use the following test methods to determine compliance with the emission standards for dioxins and furans:
(e) The owner or operator of a secondary lead smelter shall determine the dioxins and furans toxic equivalency through the following procedures:
(1) Measure the concentration of each dioxins and furans congener shown in the following table using 40 CFR 60, Appendix A-7, Method 23*:
| Dioxin/furan congener | Toxic equivalency factor (TEQ) |
|---|---|
| 2,3,7,8-tetrachlorinated dibenzo-p-dioxin | 1 |
| 1,2,3,7,8-pentachlorinated dibenzo-p-dioxin | 0.5 |
| 1,2,3,4,7,8-hexachlorinated dibenzo-p-dioxin | 0.1 |
| 1,2,3,7,8,9- hexachlorinated dibenzo-p-dioxin | 0.1 |
| 1,2,3,6,7,8- hexachlorinated dibenzo-p-dioxin | 0.1 |
| 1,2,3,4,6,7,8-heptachlorinated dibenzo-p-dioxin | 0.01 |
| Octachlorinated dibenzo-p-dioxin | 0.001 |
| 2,3,7,8-tetrachlorinated dibenzofuran | 0.1 |
| 2,3,4,7,8-pentachlorinated dibenzofuran | 0.05 |
| 1,2,3,7,8-pentachlorinated dibenzofuran | 0.5 |
| 1,2,3,4,7,8-hexachlorinated dibenzofuran | 0.1 |
| 1,2,3,6,7,8-hexachlorinated dibenzofuran | 0.1 |
| 1,2,3,7,8,9-hexachlorinated dibenzofuran | 0.1 |
(2) Correct the concentration of dioxins and furans in terms of toxic equivalency to seven percent (7%) oxygen using the following equation: 
| Where: | Cadj | = | Dioxins and furans concentration adjusted to seven percent (7%) oxygen. |
| Cmeas | = | Dioxins and furans concentration measured in nanograms per dry standard cubic meter. | |
| (20.9-7) | = | Twenty and nine-tenths percent (20.9%) oxygen minus seven percent (7%) oxygen (defined oxygen correction basis). | |
| 20.9 | = | Percent of oxygen concentration in air. | |
| %O2 | = | Percent of oxygen concentration measured on a dry basis. |
*These documents are incorporated by reference. Copies may be obtained from the Government Printing Office, 732 North Capitol Street NW, Washington, D.C. 20401 or are available for review and copying at the Indiana Department of Environmental Management, Office of Air Quality, Indiana Government Center North, Tenth Floor, 100 North Senate Avenue, Indianapolis, Indiana 46204.
(Air Pollution Control Division; 326 IAC 20-13.1-12; filed Jan 30, 2013, 12:34 p.m.: 20130227-IR-326110774FRA; readopted filed Oct 18, 2024, 2:09 p.m.: 20241113-IR-326230809RFA)