b) The Department will accept applications for CAUCCLs for 14 calendar days after the date indicated on the Department's website as the commencement date for accepting applications.
2) The proposed physical address of the cultivation center;
5) The details of any administrative or judicial proceeding in which any of the principal officers or board members of the cultivation center:
6) Cultivation, processing, inventory, and packaging plans;
14) If a partnership, the names and addresses of all partners, both general and limited (Section 85 of the Compassionate Use of Medical Cannabis Program Act) and any partnership or joint venture documents;
15) If a limited liability partnership, the names and addresses of all partners, and any partnership or joint venture documents;
17) If a limited liability company:
20) A copy of the current local zoning ordinance or permit and verification that the proposed cultivation center is in compliance with the local zoning rules and distance limitations established by the local jurisdiction;
28) If any principal officers or board members are currently, or have previously been, licensed or authorized in another state or jurisdiction to produce or otherwise deal in the distribution of cannabis in any form, the following:
29) A plan describing how the cultivation center will address each of the following:
31) The applicant's recycling plan describing the following commitments:
32) A statement describing the applicant's commitment to comply with local waste provisions. A cultivation facility must remain in compliance with applicable State and federal environmental requirements, including, but not limited to:
33) A commitment to use resources efficiently, including energy and water.
A) Lighting
The Lighting Power Densities (LPD) for cultivation space does not exceed an average of 36 watts per gross square foot of active and growing space canopy, or all installed lighting technology shall meet a photosynthetic photon efficacy (PPE) of no less than 2.2 micromoles per joule fixture and shall be featured on the Design Lights Consortium (DLC) Horticultural Specification Qualified Products List (QPL). In the event that DLC requirement for minimum efficacy exceeds 2.2 micromoles per joule fixture, that PPE shall become the new standard;
B) HVAC
C) Water Application
34) If applicable, the applicant's status as a Social Equity Applicant, as demonstrated by:
A) Evidence of the applicant's status as an "Illinois resident" as demonstrated by incorporation documents, or, if applying as an individual, at least 2 of the following:
B) A person must have been domiciled in the State for a period of 30 days to be an "Illinois resident" as used in the application; and one of the following:
e) The applicant shall sign a notarized statement certifying that:
3) The applicant has actual notice that, notwithstanding any State law: