- a) Well Repair. Wells constructed prior to the adoption of this Part may not meet the criteria established. When a well is to undergo modification, reconstruction, or repair, the work shall include those changes necessary to make the well conform to this Part.
b) Well Pits.
- 1) No new well pits shall be allowed.
2) Existing pits will be accepted if the following conditions exist:
- A) The well pit shall be structurally sound and watertight. The casing shall extend at least twelve (12) inches above the pit or basement floor and have a well seal to prevent contaminants from entering the well.
- B) A watertight manhole and cover must be provided for the well pit.
3) Existing pits that are not in compliance with subsection (b)(2) shall:
- A) Be eliminated after the installation of a pitless well adapter unit on the water well casing. The floor or one wall of the pit shall be broken or removed and the pit filled with earth; or
- B) Be used as a tank pit for water storage or as a valve pit for water distribution provided the pit is not subject to flooding. A pitless well adapter or pitless adapter unit shall be installed on the water well casing.
c) Pitless Well Adapters.
- 1) The installation of a pitless well adapter or a pitless adapter unit shall not be considered modification of a water well.
- 2) The repair of damaged casing above the pitless adapter shall not be considered modification of a water well if the installation is in accordance with Section 920.90(c).
- 3) When a buried well seal is removed, the extension of the casing to above ground shall not be considered modification of a water well if the installation is in accordance with Section 920.90(c).
(Source: Amended at 46 Ill. Reg. 15751, effective August 30, 2022)