Ill. Admin. Code tit. 77, § 675.120
a) Screening Procedures
1) For the screening stage of identification audiometry, the following pure-tone frequencies and intensity levels shall be used:
| Test Frequencies in | Screening Levels in |
| Cycles Per Second | Decibels |
| 500 Hz | 25 dB |
| 1000 Hz | 25 dB |
| 2000 Hz | 25 dB |
| 4000 Hz | 25 dB |
b) Pass – Fail Criteria
1) A child is considered to have "failed" the screening test, if he:
c) Threshold Test Procedures
It is recommended that the right ear be tested first. Always begin testing at 1000 Hz. After determining threshold at 1000 Hz, continue with the following frequencies: 2000, 4000, 8000, 500 and 250 Hz. Then switch to the opposite ear and repeat the entire procedure at 1000, 2000, 4000, 8000, 500 and 250 Hz.